Fault Diagnosis Method of Hydro-generating Unit based on Immunology Principles

Liu Zhong,Zhou Jianzhong,Zhang Yongchuan,Zou Min
DOI: https://doi.org/10.3969/j.issn.0559-9342.2007.03.018
2007-01-01
Abstract:In order to solve the problems such as complex modeling,large sample demands and discontinuous learning in the fault diagnosis techniques,a new method based on immunology principles is proposed.Taking state symptoms as antigens,and detectors under different fault modes as antibodies,the normal conditions and anomaly are distinguished via negative selections.Memory antibodies that can identify the structures of antigens are generated via the mechanism of clonal selection.Fault types are determined by the maximum fault membership.The proposed method was applied to the vibration diagnosis of hydroelectric generating unit.Results indicated that the high diagnosis accuracy with low demands on fault samples,and the merits of this method in application as well.
What problem does this paper attempt to address?