Analysis and Control of Parasitic Oscillation of the Output Rectifier Bridge in DC/DC Converter

刘申月,王书强,王立伟,贲洪奇
DOI: https://doi.org/10.3969/j.issn.1000-100x.2009.10.032
2009-01-01
Abstract:By considering the leakage inductance of the transformer and parasitic parameters of the diode,an equivalent model of current commutation of rectifiers in transformer's second side of isolated DC/DC converter is built.Using this model,the cause of parasitic oscillation of the output rectifier bridge is analyzed.The effects of electrical parameters on the parasitic oscillation are discussed and several methods to suppress the parasitic oscillation are introduced,merits and faults of each method are given.RC snubber circuit is used in the design of 13 kW phase-shifted full-bridge converter.Experimental results show that RC snubber circuit can suppress the parasitic oscillation of the output rectifier bridge effectively.
What problem does this paper attempt to address?