Clinical application of HERO 642 rotary Nikel-Titanium instrument

ZHU Chen-xi,YANG Xiao-feng,GU Zhi-yuan
DOI: https://doi.org/10.3969/j.issn.1003-9872.2006.01.013
2006-01-01
Abstract:Objective To evaluate the clinical application of HERO 642 Ni-Ti instrument to the root canal treatment. Methods 53 patients were selected randomly divided into two groups: HERO 642 group and stainless steel K file group. The quality of obturation was determined by radiographs, and the ratio of interappointment emergencies and working time were measured and analysed. Results [WTBZ] The rate of best root canal obturation in HERO 642 group was better than that in ss-k group(P<0.01), and the working time of HERO 642 group was shorter than that of the other (P<0.01). There was no statistical difference between the two groups in the rate of interappointment emergencies. Conclusion The appliance of HERO 642 to root canal preparation may improve the quality of obturation and shorten the working time.
What problem does this paper attempt to address?