Structural Improvement and Application of Pulled Type Fixed Valve Pump

WANG Ze-xiang,LI Yong-bing,WANG Fang,ZHU Hong-wei,DONG He-ru
DOI: https://doi.org/10.3969/j.issn.1001-3482.2012.12.017
2012-01-01
Abstract:For the conventional type of subsurface sucker rod pump,the puller extractor of standing valve usually adopts salvaged head and salvaged claw to help to pull up the standing valve.This method is widely used in foreign oilfield as it is no need to pull out the tubing string to check the subsurface sucker rod pump;it can save the working time and reduce the cost.But with the increasing of the depth of wells,it becomes more and more difficult to salvage the standing valve of subsurface sucker rod pump from the wells,and may increase the working time.So the puller extractor of standing valve was redesigned and optimized,we the structure was changed to use thread connection and loosen type.The improved structure was more reliable and used in Oman Daleel Oil field 14 times.As statistics,the average pump efficiency can reach 67.5% and the average daily fluid production can reach 44.35 ton / day,it approves that the application effect is well.