Preliminary study of Isotropic MR Imaging in the examination of the ankle: compared with conventional examination technique

ZHENG Ling,GU Hai-feng
DOI: https://doi.org/10.3969/j.issn.1006-9011.2012.11.051
2012-01-01
Journal of Medical Imaging
Abstract:Objective To explore the image quality and diagnostic accuracy of isotropic MR Imaging and conventional examination technique in the ankle joint examination.Methods Some parameters of the 2D-FSE sequence were adjusted to make the change to Isotropic three-dimensional sequence of 3D-FSE-Cube.Then use each of them scan hed the ankle of 10 healthy volunteers.Finally,we analyzed the quality,blur artifacts,signal-to-noise ratio and contrast noise ratio of the images.Results 3D-FSE-Cube 1D sequence obtained SNR of articular cartilage,synovial fluid and muscle was significantly higher than the 2D-of FSE sequence.3D-2D FSE-Cube sequence with 2D-of FSE sequence had no significant differences.In addition to more obvious ambiguity on the 3D-FSE-Cube sequence,there was no significant difference in image quality and artifacts between 2D-of FSE sequence and 3D-FSE-Cube sequence.Conclusion Either in the signal to noise ratio of the image or the Diagnostic accuracy,magnetic resonance isotropic examination techniques possess an absolute advantage.