Determination of N-Methylpyrrolidine in Cefepime Dihydrochloride by Ion Chromatography with Conductivity Detector

JIN Yun,HANG Yi-ping,YANG Chun-ying
DOI: https://doi.org/10.3969/j.issn.1001-8255.2009.07.015
2009-01-01
Abstract:An ion chromatography with conductivity detector by direct inlet was established for the determination of N-methylpyrrolidine in cefepime dihydrochloride. A high capacity cation exchange column was used,with the mobile phase of 9 mmol/L HNO3(containing 15% acetonitrile). The flow rate was 0.9 ml/min,the components were eluted in 35 min. The calibration curve of N-methylpyrrolidine was linear in the concentration range of 0.9-25 μg/ml (r=0.999 7). The detection limit was 0.095 μg/ml. The average recovery was 95.3%.