Liquid chromatographic determination of free hydroxyproline in serum

BIAN Jing,ZHOU Ye-ping,CHEN Zhi-gang,ZHEN Jian-cun,SHAO Hong
2008-01-01
Abstract:OBJECTIVE To establish an HPLC method to measure free hydroxyproline(HYP) in serum.METHODS Both o-phthalaldehyde(OPA) and 9-fluorenylmethylchloroformate(FMOC) were used in pre-injection reaction.HYP was assayed by HPLC with the following conditions:ODS C18 column,UV detective wavelength 265 nm,flow rate 1.0 mL·min-1,and gradient elution of sodium acetate buffer and acetonitrile.RESULTS The analytical time was only 27 min.RSD within a day and between days were 1.95 % and 2.02%.Recovery rate was(100.5±4.0) %.Linear range was 0.26 ~64 mg·L-1.The method was applied in healthy blood donors.The average values of serum free hydroxyproline of male and female were(1.4±0.5) mg·L-1 and(1.10±0.32) mg·L-1,respectively.CONCLUSION This method can directly detect free hydroxyproline in serum without dealing with derivative product is suitable for using in clinic.
What problem does this paper attempt to address?