A Study of MR Diffusion-Weighted Imaging of Implanted Osteosarcoma

SUN Jun-hui,CUI Jian-ling,LI Jian-ping
DOI: https://doi.org/10.3971/j.issn.1000-8578.2006.12.015
2006-01-01
Abstract:Objective To evaluate the characteristic of DWI of SD rat osteosarcoma and the role of DWI in the identification of the necrosis of the osteosarcoma. Methods The osteosarcomas were developed by transplanting tumor cells(UMR-106) in the back of SD rats by subcutaneous injection. The planted tumors were scanned with MR conventional sequences. EPI-DWI were also performed. The MR images were compared with the pathologic sections. Results The percentage of the total blood vessel areas in the axial sections of the tumors did not correlate to its corresponding ADC values. The necrotic areas of the tumors could be identified by contrast enhanced T_ 1 -SE, and its sensitivity was 86.7% (13/15), specificity was 38.5%(15/39) and veracity was 51.9% (28/54). It was feasible to identify the necrotic regions by ADC values, and its sensitivity was 93.3% (14/15), specificity was 94.9% (37/39) and veracity was 94.4% (51/54).Conclusions The microcirculation of the tumors can hardly affect its corresponding ADC values with high b value. The necrotic areas of the SD rat osteosarcomas could be differentiated by DWI more accurately and earlier than traditional MRI sequences and post contrast scan.