Studies of improving the interpreation accuracy of through annulus log

Huang Chunhui,Hu Jinhai,Shan Hongkuan,Shan Fujun,Yang Qi
DOI: https://doi.org/10.3969/j.issn.1004-9134.2011.04.030
2011-01-01
Abstract:The production logging interpretation normally adopts the average values of measured flowrate and water cut in a certain time,then the measured watercut is interpolated based on the calibration chart according to the average values.Analysis shows there is a certain error in this method.In order to reduce the error generated by average method,and improve the interpretation accuracy of well logging data,a new point by point correction method to interpret through annulus well logging data is developed.The point by point correction method requires down hole tool to simultaneously measure and transmit flowrate and water cut mixture values to up ground in real time during on-site well logging. The ground data acquisition system can simultaneously collect the two data in real time.Finally,according to water cut calibration chart the measured water cut is calculated by using interpolation method.The calculated results show that the new correction method can effectively reduce the error,and improve the interpretation accuracy of through annulus well logging data.
What problem does this paper attempt to address?