Pilot study on the shortened process by ultrafiltration adapting to conventional coagulation/sedimentation for drinking water treatment
Yizhong Xie,Yuhao Duan,Qilan Feng,Jiayu Tian,Shenghui Jiang,Zhiwei Zhao,Jie Chen,Wenjie Yang,Weipei Chen
2015-01-01
Abstract:Aiming at the influent in sedimentation tank,the water samples from the central part of the sedimentation tank,and the effluent from the sedimentation tank,respectively,pilot-scale experiments have been carried out. When coupling with coagulation/sedimentation at different sections,the changes of the ultrafiltration(UF) membrane effluent water quality and the fouling characteristics of ultrafiltration membrane are investigated. The results show that,as far as turbidity,CODMn and UV254 are concerned,the coupling process of coagulation/sedimentation-ultra filtration at different sections is basically equivalent to the purification of water quality. However ,from the viewpoint of membrane fouling,it is found that when the coupling section was set at the inlet of sedimentation tank,the membrane fouling of the UF membrane was very serious. On the other hand,if the coupling section was set at the outlet of the sedimentation tank,the membrane fouling was significantly reduced. When the coupling section was set at the central part of the sedimentation tank,the membrane fouling rate was not too serious,although a slightly higher. Meanwhile,the floor area of the water plant can be reduced remarkably.