Determination of Related Substances in Tauroursodeoxycholic Acid Capsule by HPLC

ZHANG Xiao-yan,CUI Rui,JIA Jian-jing,LIU Li-jun,ZHANG Dan
2012-01-01
Abstract:OBJECTIVE To establish an RP-HPLC method for the determination of related substances in Tauroursodeoxycholic acid capsule.METHODS Analysis was carried out on a Diamonsil C18 column(150 mm×4.6 mm,5 μm) using phosphate buffer(0.02 mol·L-1 NaH2PO4)-acetonitrile(60:40)(adjusting pH to 5.5 with phosphoric acid) as mobile phase at detective wavelength of 205 nm.The flow rate was 1.0 mL·min-1 and the temperature was 30 ℃.RESULTS The linear range of Tauroursodeoxycholic acid was 0.9694-96.94 μg·mL-1(r=0.9999),and the detection limit was 0.3635 ng with the lower limit of quantitation of 1.454 ng.The linear range of Taurochenodeoxycholic acid was 0.9443-94.43 μg·mL-1(r=0.9999),and the detection limit was 9.447 ng with the lower limit of quantitation of 23.62 ng.The method recovery was 99.54%.CONCLUSION The method is accurate,sensitive and rapid for quality control of trace impurities in Tauroursodeoxycholic acid capsule.