Study Onoptimization of Flow Measurement Accuracy of of Drainage Straight Pipe

Xiao-zhou TANG,Yun ZHU,Cheng-cheng XIE
DOI: https://doi.org/10.3969/j.issn.1006-9348.2012.07.099
2012-01-01
Abstract:Research the improvement of flow measurement accuracy of drainage straight pipe.As the current traditional measurement methods cannot effectively reduce the drainage straight pipe installation error in actual measurement,leading to low precision of flow measurement.In order to optimize the flow measurement accuracy of the drainage straight pipes,a turbulence model of drainage straight pipe was presented based on two-equation theory of fluid turbulence.CFD software Fluent was used to simulate the change in the pressure difference in front and rear of orifice,which varries with the installing angles of the straight sections,and obtained the pressure difference value after eliminating the static pressure.Simulation results show that as the velocity increases,the influence of the change in installing angles on measurement accuracy decreases.The experiment proves that single drill tapping method is more accurate among the whole measurement methods and is a good method to deal with the flow measurement accuracy problems.
What problem does this paper attempt to address?