Design and Simulation of Coherent Lidar System for Measurements of CO_2 and wind field with 1.5 Microns

Lei Wu-hu
2008-01-01
Abstract:Concentration of CO2 and wind field in low altitude can be measured by coherent lidar simultaneously,with better signal-to-noise ratio(SNR) than incoherent detection.At present the 1.5 microns laser is both eye-safe and low-cost for building a lidar system.The 1.5 microns wavelength will also be the best candidate for the future aerosol lidar.In this paper,the principles of detecting concentration of CO2 and wind field with coherent lidar are described and the design details of coherent lidar with 1.5 microns are given.From the simulated SNR,it can be concluded that heterodyne detection of wind field and concentration of CO2 with 1.5 microns is feasible and the estimated SNR at 3km distance in daylight can be better than 10 for 3 minutes integraton.