Method for Elimination of DC Offset and Steady State Error for Voltage Module Flux Observer

ZHANG Xing,QU Wen-long,LU Hai-feng
DOI: https://doi.org/10.3969/j.issn.1003-3076.2006.01.010
2006-01-01
Abstract:The flux observer based on voltage has been obtained more attention for its clear concept and simple usage.However,the inherent initial value error and DC offset problem can not be completely removed using the existing low pass filter(LPF) method.Besides,LPF also brings steady state error.In the proposed method,the pure integrator is replaced by low pass filter and high pass filter(HPF) in series to eliminate the initial value error and DC offset effect,and the steady state error can be compensated completely.So the flux has no amplitude and phase error.The compensation formula is derived with time phasor method.The novel observer is simple and easier to apply to digital system.Both simulation and experimental results show that the induction motor performance in low speed region has been improved remarkably.This also verifies the effectiveness of the novel observer.
What problem does this paper attempt to address?