The Application of Fitting Formula for Specific Volume and Enthalpy of Water and Steam in the Saturated Steam Industrial Boiler

辛少杰,虞亚辉,潘玉明,董勤霞,余岳峰,罗永浩
DOI: https://doi.org/10.3969/j.issn.1004-8774.2009.06.009
2009-01-01
Abstract:Based on the calculation data according to the new international industrial standard IAPWS-IF97 formula,deduced the function which is suitable for the pressure grade of saturated steam industrial boiler by least square method.The function with absolute pressure p as a variable fitted the dry steam enthalpy h″,specific volume of dry saturated steam v″,saturated water enthalpy h′,latent heat of vaporization r(Δhv) and specific volume of saturated water v′,ultimately gave the expression of water enthalpy hgs and water density ρgs with pressure pgs and temperature tgs as variables.The functional expression characterized with high precision,wide range of application,convenient and useful,could be applied to saturated steam industrial boiler performance test,thermal statistics,energy audit.
What problem does this paper attempt to address?