STUDY ON THE CONTAMINATION AND CLEANING OF ULTRA-LOW-PRESSURE REVERSE OSMOSIS MEMBRANE PROCESSES FOR TREATING THE ACID MINE DRAINAGE

Zhong Changming,Qin Xiaohai,Xu Zhenliang
DOI: https://doi.org/10.16796/j.cnki.1000-3770.2009.05.033
2009-01-01
Abstract:The membrane contamination and cleaning in the acid mine drainage(AMD) was studied by using ultra-low-pressure reverse osmosis membrane,the results showed that:the different conditions of their pretreatment and reverse osmosis,the pollution degrees is different,even the same cleaning conditions,the cleaning effect is different.The appropriate cleaning condition is:the flux of the concentration liquid is always 1 200 L·h-1 circumstances,firstly,closing the valve of the permeation liquid,reverse osmosis clean membrane 15 min using the pure water(0.6 MPa,at room temperature) and then open the valve of reverse osmosis permeation liquid 15 min;Then using 0.1% NaOH reverse osmosis clean membrane 30 min(1.0MPa,45 ℃);followed by 0.3% H2O2 immersion 16 h;Finally,reverse osmosis clean membrane 30 min using the pure water(0.6 MPa,at room temperature),the membrane flux return to above 99 percent.
What problem does this paper attempt to address?