EFFECTS OF CASTING CONDITIONS ON PVDF MICROFILTRATION MEMBRANE PERFORMANCE BY IMMERSION PRECIPITATION PHASE INVERSION

Zhang Jie,Wang Qiaoying,Wang Zhiwei,Wu Zhichao
DOI: https://doi.org/10.3969/j.issn.1000-3770.2013.07.014
2013-01-01
Abstract:In this study,the poly(vinylidene) fluoride(PVDF)-based microfiltration membrane was prepared via immersion-precipitation phase inversion method.The effects of the preparation conditions,such as evaporation time,coagulation bath temperature,scraper clearance and casting speed on the membrane morphological structure,porosity,permeability and fouling performance were systematically investigated.The results showed that with the extending of evaporation time,the porosity decreased and pure water flux increased firstly and then decreased.The membranes prepared with 10 s as the evaporation time presented the best anti-fouling property.The porosity,pure water flux and fouling rate of the membranes increased with the initial increasing of the coagulation bath temperature,and then decreased when the coagulation bath temperature was above 45 ℃.With the increment of scraper clearance,pure water flux gradually decreased,and the porosity exhibited the tendency of increasing firstly and then decreasing.The fouling performance was optimal when the scraper clearance was 0.25 mm.
What problem does this paper attempt to address?