Fault Analysis and Troubleshooting of Oil-film Oscillation for An Axial Compressor

瞿雷,侯新军,金颖,廖与禾,屈运动
DOI: https://doi.org/10.3969/j.issn.1006-8155.2013.03.016
2013-01-01
Abstract:An AV40 axial compressor was repeatedly stopped running due to abruptly vibration and fluctuation in the process of starting and speeding up, which resulted in the starting failure of the four-in-one nitric acid unit. It was confirmed that the main reason of the fault was that there existed obvious oil-film oscillation to induce the oil-film instability in the moment, by means of analyzing features such as spectrum, orbit ,etc., combining with the time when the fault occurred and the characteristics of journal bearing. Based on the summary about the methods of eliminating the fault of oil-film oscillation in the field, the journal bearing with mild wear at the outlet side was replaced with a new one, so as to decrease the top clearance and improve the stability of the bearing. The final result of trail run of the compressor demonstrates that the maintainance measures above are simple and effective, and the fault of oil-film oscillation has been completely eliminated.
What problem does this paper attempt to address?