Influence Analysis of Cable-Nets Structure′s Prestress in Glass Curtain Wall on Bearing Property of Side Frame Column

DING Dayi,WANG Yuanqing,SHU Chang,SHI Yongjiu,NIU Zhongrong
2012-01-01
Abstract:The bearing property of biaxial bended columns needed to be analysed in practical engineering projects,which may provide guidances for the design.Characteristic value buckling and nonlinear buckling on the side column of Hefei Xinqiao international airport 3 section terminal were analysed by ANSYS software.What′s more,the whole structure model and single rigid frame model were respectively calculated and compared with each other in different conditions,and then the most unfavorable internal force combination was extracted for the calculation.Furthermore,the actual bearing property of the side column was checked.In the most unfavorable conditions,the difference between the maximum internal force of side column calculated in the whole structure model with that calculated in the single rigid frame model was less than 16.6%,which all meeted to the requirement of the related formula of the code for design of steel structures(GB50017-2003),and the load stability coefficient for the buckling analysis was about 6.0.The design of side column conformed to the requirements of the relevant specification,and got verification of the calculation results of the finite element model.Moreover,calculation and analysis methods proposed in the paper could also become the reference to similar projects.
What problem does this paper attempt to address?