Abstract:Objective To simulate the computational hemodynamics of cranial aneurysms and analyze the hemodynamics of cranial aneurysms with broad neck and narrow neck. Methods Representative DSA images of ICA-PCoA aneurysm patients (broad neck and narrow neck) were chosen. Photoshop, Matlab,Ansys and Fluent softwares were used to simulate the computational hemodynamics of cranial aneurysm in a whole cardiac cycle. Results The aneurismal simulation of hemodynamics was performed in the computers successfully. It was found there was turbulent flow in the cranial aneurysms with broad neck,but not in the ones with narrow neck. The velocity of flow in the cranial aneurysms with broad neck was between 0.057-0.156 m/s,and that in the cranial aneurysms with narrow neck was between 0.001-0.014 m/s. Conclusion As the existence of the turbulent flow in the cranial aneurysms with broad neck,cranial aneurysms with broad neck are greatly different to the ones with narrow neck in hemodynamics. Henceforth,in the interventional treatment of aneurysms,suggesting in the interventional treatment of cranial aneurysms,the velocity of turbulent flow should be lowered or the turbulent flow disappeared before embolization of the aneurysm.
What problem does this paper attempt to address?