Numerical Simulation of Hemodynamic of Intracranial Aneurysms Before and after Stent Implantation

LU Hai-tao,HUANG Qing-hai,LIU Jian-min,CHEN Jia-liang,WANG Sheng-zhang
DOI: https://doi.org/10.13481/j.1671-587x.2011.05.049
2011-01-01
Abstract:Objective To explore the effect of stent implantation on the hemodynamic characteristics of middle cerebral artery(MCA) aneurysm and analyze the effect of stent on hemodynamic factors such as wall shear stress.Methods One patient with wide-neck MCA bifurcation aneurysm was analyzed before operation and during follow-up according to clinical images and using fluid dynamics software(ANSYS software) based on computational fluid dynamics(CFD) numerical simulation methods.The blood streamlines and wall shear stress were compared in both conditions.Results There was significant change in morphology of arteries after stent implantation and the aneurysm was gone.The angle of vascular bifurcation became smaller from 196.4° to 92.5°.The aneurysm disappeared completely.The distribution of wall shear stress on the surface of aneurysm turned uniform after stent implantation.The region of high wall stress value near the neck of aneurysm was disappeared directly.Conclusion Stent implantation can change the partial hemodynamics of aneurysm and parent artery.The numerical simulation of CFD can directly reflect the hemodynamic characteristics of aneurysm.
What problem does this paper attempt to address?