Determination of Residual Organic Solvent in Alacepril by Solution-Solid Headspace Gas Chromatography

Qinghua Tang,jianying Hu
DOI: https://doi.org/10.3969/j.issn.1671-7929.2005.06.012
2005-01-01
Abstract:A solution-solid headspace gas chromatography for the determination of residual organic solvent in alacepril was established. A HSS-4A and DB-FFAP wide bore capillary column was used with 1-propanol as internal standard. The linear range for n-hexane, acetone, tetrahydrofuran, methanol, ethanol and chloroform were 1.7 ̄24.0μg·mL-1 (r=0.9991), 0.7 ̄14.6μg· mL-1 (r=0. 9990), 1.4 ̄28.2μg ·mL-1 (r=0.9985), 0.8 ̄15.2μg·mL-1 (r=0.9995), 1.4 ̄28.2μg ·mL-1 (r=0.9991) and 1.5 ̄29.4μg ·mL-1 (r=0.9983), respectively. The average recoveries of n-hexane, acetone, tetrahydrofuran, methanol, ethanol and chloroform were 99.3%, 101.9%, 105.3%, 98.5%, 100.7% and 102.0%, respectively. The lowest test limits of n-hexane, acetone, tetrahydrofuran, methanol, ethanol and chloroform were 0.06μg·g -1, 0.04 μg·g-1, 0.04μg· g-1, 0.09 μg· g-1, 0.07μg·g-1 and 0.15 μg· g -1, respectively. The method was simple, accurate, sensitive and reproducibility.
What problem does this paper attempt to address?