High-order resonance of three axis suspension wire actuator in optical pickup

Zhang Bu-Qing,Ma Jian-She,Cheng Xue-Min,Pan Long-Fa
DOI: https://doi.org/10.3321/j.issn:1004-924x.2007.11.022
2007-01-01
Optics and Precision Engineering
Abstract:In order to improve the servo control bandwidth of the three axis actuator in a optical pickup,the high-order resonances in the focusing/tracking directions are studied.The induced mechanism,physical model,modal distribution and the test approach on the high-order resonance are studied.The low angle yawing model is established according to the actual stress on the three axis actuator.Then the modal distribution and modes are analyzed and calculated with the finite element method.Finally,the test method of the high-order resonance is introduced and the actuators with assemble errors are measured.The test results show that the pitching resonance usually appears on the focusing performance curve under the frequency of 1 700 Hz and the yawing resonance usually appears on the tracking performance curve under the frequency of 4 800 Hz.The experiment results are consistent with the finite element analysis.The results also show that the high-order resonance is the inherent attribute of the three axis actuator,which can be restrained by reducing the assemble error of the three axis actuator.
What problem does this paper attempt to address?