Effect of Gas Distributor on Bubble Size Profiles in A Bubble Column

Ye Zeyue,Zhang Lijuan,Shi Kangsheng,Li Tao,Fang Dingye,Ying Weiyong
DOI: https://doi.org/10.3969/j.issn.1006-6829.2007.04.014
2007-01-01
Abstract:Axial bubble size distribution and gas holdup profiles were determined under the ambient temperature and pressure using the dual electrical conductivity probes technology in a gas-liquid bubble column, and the effects of the gas distributor on the performance of the bubble column were researched. The results indicated that the regime transfer was delayed when the open area increased. The effects of the open area on the bubble size distribution were discussed for operating in two flow regimes: homogeneous regime and transition regime. The maximal stable bubble diameter was decreasing and gas hold-up increasing when the open area was increasing in transition regime while the effect was neglected in homogeneous regime. The initial bubble diameter was increasing when orifice diameter increased, whose effect is limited to the distribution regime. An empirical correlation which took into account the effect of the gas distributor to predict the time averaged bubble diameter was derived and it is also found to be in good agreement with the experiment data.
What problem does this paper attempt to address?