Abstract:The Venturi bubble generator was applied in the micro bubble column reactor based on the airwater system in order to analyze the influences of operating conditions and structural parameters on the bubble size distribution and bubble Sauter mean diameter by the high speed camera.Results show that the bubble Sauter mean diameter increases under higher gas flow rate whereas it decreases under higher liquid flow rate.The bubble Sauter mean diameter reaches the minimum when air holes are located at the Venturi throat.When liquid velocity at the Venturi throat ranges from 0.983 to 2.949 m/s,bubble Sauter mean diameter decreases with the increase in the number of air holes.While liquid velocity at the Venturi throat ranges from 3.932 to 4.915 m/s,bubble Sauter mean diameter decreases at first and then slightly increases.The number of the air hole has little influence on bubble Sauter mean diameter when it is more than 6.An empirical correlation of bubble Sauter mean diameter based on ReL and ReG was proposed through the regression analysis.The calculated values accorded well with the experimental data.