Numerical Simulation in the Piggery under Vertical Ventilation

He Cheng,Niu Zhiyou,Liao Na
DOI: https://doi.org/10.3969/j.issn.1003-188X.2009.08.007
2009-01-01
Abstract:This paper reported a study on piggery with the help of CFX software based on CFD.The three-dimensional steady state numerical simulation of airflow and temperature pattern was undertaken in the piggery under vertical ventilation,where fans were fixed on the end wall and fans were fixed on four conners.Simulation results showed that both of their airflow distribution were uniform.Under the condition that fans were fixed on the end wall,air temperature was 30~31℃ close to outlets;Under the condition that fans were fixed on four conners,the temperature was lower than 30℃ in most of the piggery.Results indicated it was suitble that wet-pads were fixed at the middle of side walls and fans were fixed on four conners under vertical ventilation in piggery whose length was larger.
What problem does this paper attempt to address?