Effect of Cooling Pad-fan System on Thermal Environment and Air Quality in Pig House with Fermentation Bed in Winter and Summer in Beijing

Zhongying LIU,Yao GUO,Yuqing XIE,Qiuting ZHANG,Meizhi WANG,Zhonghong WU
DOI: https://doi.org/10.3969/j.issn.1673-1182.2017.12.010
2017-01-01
Abstract:To cope with the problem of severe heat stress in summer and ineffective ventilation in winter for pig house with fermentation bed in Beijing area,a negative-pressure cooling pad fan system was installed in pig house with fermentation bed to study the indoor heat environment and air quality after installation.The results show when outdoor daily average temperature was 33.7 ℃ in summer,the daily average temperature in pregnancy and fattening pig houses were 3.0 ℃ and 2.8 ℃ (P<0.05) lower than that of the control pig house,the effective environment temperature(EET) were 10.0 ℃ and 9.8 ℃ (P<0.01) lower respectively,the pigs were comfortable while pigs in control house were in stress;at 14:00 when the temperature is the highest,the surface temperature of fermentation bed,sow's respiratory frequency and skin temperature of pigs in pregnancy test house were 2.9 ℃,17.2 times/min and 1.6 ℃ (P<0.05) lower than that in pregnancy control house.In winter when the temperature was comparatively high and the fan was operating for ventilation,the indoor temperature in test house dropped 0.4 to 1.3 ℃,the concentration of NH3 and CO2 as well as bacteria total count decreased by 58.1% to 71.2%,49.6% to 53.5% and 21.9% to 36.0%;when the indoor relative humidity was above 75% and the fan was operating,the indoor PM2.5 and PM10 dropped by 12.3% to 20.0% and 11.3% to 24.9%,when the indoor relative humidity was below 75%,the operation of fan would increase the dust concentration.Therefore,the pad-fan system in fermentation pig house can both meet the need of cooling and ventilation in summer,and improve the air quality of humid environment in winter,but small air speed is required under appropriate relative humidity in winter.
What problem does this paper attempt to address?