Determination of Semi-Volatile Organic Compounds in Source Water by GC/SPME

LI Chun-yu,DAI Xuan-li
DOI: https://doi.org/10.3969/j.issn.1006-2009.2010.02.013
2010-01-01
Abstract:18 semi-volatile organic compounds in source water were determined by GC/ECD with solid-phase micro-extraction technology.By optimizing extraction condition of fibers,time,temperature,ph value,rotor speed and ion intensity,the results showed good linearity;detection limits of 18 compounds between 0.000 2 μg/L and 0.1 μg/L;and spiked recoveries of samples between 84.3% and 109%.
What problem does this paper attempt to address?