Transcatheter closure of giant congenital coronary artery fistula with patent duct occluder

ZHONG Li,SONG Zhi-yuan,RAN Bo-li,ZHANG Zhi-hui,ZHANG Qian
DOI: https://doi.org/10.3321/j.issn:1000-5404.2008.04.021
2008-01-01
Abstract:Objective To report our experience in using the patent duct occluder for occlusion of giant coronary artery fistulae (CAF) Methods Using echocardiogram and selective coronary arteriography,we diagnosed giant CAF from the right coronary artery to the right ventricle in a 43-year-old female An arteriovenous wire loop was established via the aorta,coronary artery,and fistula to the right ventricle,right atrium and inferior vena cava A long sheath was delivered antegradely to deploy the occluder in the CAF via the venous system Results The CAF was occluded completely No residual shunt or other complications were observed during the 4-month follow-up Conclusion Transcatheter closure of giant coronary artery fistulas with patent duct occluder is feasible and safe in the anatomically suitable vessels