Application of 3D Hydrolysis Detachable Coils and Ordinary Coils in Percutaneous Closure of Coronary Artery Fistula

ZHU Zhong-sheng,CHEN Shao-liang,YE Fei,ZHANG Jun-jie,TIAN Nai-liang,LIN Song,LIU Zhi-zhong,DUAN Bao-xiang
DOI: https://doi.org/10.3969/j.issn.1008-0074.2010.06.24
2010-01-01
Abstract:Objective:To investigate the application effects of 3D hydrolysis detachable coils and ordinary coils in percutaneous closure of coronary artery fistula(CAF).Methods:A total of 29 patients who underwent coronary angiography(CAG) and were found coronary artery fistula which were suitable for percutaneous closure.The percutaneous closure was performed from January 2003 to August 2009.Results:In 15 CAF cases used ordinary coils,successful rate was 60%(9 cases /15cases) and failed in 40%(6/15);in 14 cases used 3D coils(plus ordinary coils when necessary),successful rate was 57.1%(8/14) and unsuccessful rate was 42.9%(6/14).There were no significant difference between successful rates of two groups(P=0.353).TIMI flow grade of fistula in two groups showed no significant difference after closure(P=0.277).All patients were followed up by telephone and no severe complication related to closure procedures occurred until May 2010.Conclusion:Both ordinary coils and 3D hydrolysis detachable coils can be successfully used in percutaneous closure of coronary artery fistula,but effects of them have no significant difference.
What problem does this paper attempt to address?