EPANET based simulation on variable pressure mode with VFPs in water supply system

Wang Qi,Liu Shuming,Chen Jinduan,Meng Fanlin
DOI: https://doi.org/10.13789/j.cnki.wwe1964.2009.s2.103
2009-01-01
Abstract:The operation mode of pumping station with variable frequency pumps(VFP) in water supply system is similar to the variable pressure mode with VFPs.EPANET provides a common framework to simulate the water supply system,which is realizable to model the operation of pumps in various kinds of conditions.Pump characteristic curve,pump speed and speed pattern are the key elements that determine the accuracy of the simulation in variable frequency mode.By combining the pump model with pressure breaker valve model in EPANET,a methodology was developed to simulate the variable pressure mode with VFPs in water supply system.A case study was conducted on one pumping station in raw water system of a city in South China.Through model calibration and validation,it showed that the model performed relatively accurately on representing the operation status in the pumping station system.