Application of Degas for Ion Temperature Profile Reconstruction from A Npa Diagnostic on Hl-2a

Xia Zhiwei,Li Wei,Yang Qingwei,Lu Jie,Yi Ping,Gao Jinming
DOI: https://doi.org/10.1088/1009-0630/15/2/04
2013-01-01
Abstract:On HL-2A, the ion temperature profile can be roughly estimated by analyzing the energy spectrum of the neutral particles that escape from core plasma through 11 different spatial channels. However, this profile deviates from the real radial distribution because of the averaging and attenuation effects. The DEGAS code is used to estimate these effects and reconstruct a more reasonable ion temperature profile by simulating these neutral spectra and making them conform to the measurements. In this paper, critical parameters that affect the escaped neutral spectra are enumerated, and an example of a reconstruction of the ion temperature profile is presented based on experimental data.
What problem does this paper attempt to address?