Electromagnetic Separation Effect of Inclusions in Al-melt

REN Zhen-guo,CAO Zhi-qiang
2005-01-01
Abstract:The effect of parameters, electrical source power, purification time and pipe radius on the purification efficiency of Al-24% Si hypereutectic alloy was investigated in an alternating magnetic field. The purification effect was better when the electrical source power was higher, the purification time was longer and the piper radius of the separator was thinner. The end effect occurred in the Al-melt of work-coils end. The separated primary Si particles incorporated at the separator pipe wall, and grew up into the Al-melt, which affected the purification effect ; but it was constrained when the diameter of separator pipe was 10 mm and the power was 10 kW. The optimal effect was achieved when the acting time was 30 s.
What problem does this paper attempt to address?