Study on Degradation of Paranitrophenol Wastewater by Hydro-Plasma

刘自力,孙建华
DOI: https://doi.org/10.3969/j.issn.1671-4229.2008.05.008
2008-01-01
Abstract:Removal rate of 91.2% for Paranitrophenol was obtained after 120 min discharge at 30 kV of peak voltage,150 Hz of frequency and 2 mm of distance in needle-balloon continuous reactor with gas bubbling. The study shows Original concentration,pH,conductivity affect the degradation. Lower original concentration,Original pH and lower conductivity can improve degradation rate. FT-IR,high performance liquid chromatography (HPLC) and LC/MS are used to monitor the degradation process and to identify the major oxidation intermediates. Degradation pathways of them are proposed on the basis of detection of intermediates. The activity bit of paranitrophenol was attacked and permuted by hydroxyl radical.And then the quinone are detected.These products are further oxidized,eventually,mineralized into CO2,H2O,finally .So mechanism of degradation is in reason. The degradation is successful.