Determination of Arsenic in Food-Additive Phosphoric Acid by Atomic Florescence Spectrometry

ZHOU Da-Ying,GONG Xiao-Jian
2012-01-01
Abstract:The method for determination of arsenic in food-additive phosphoric acid by atomic florescence spectrometry was established.The experimental conditions were investigated and optimized,including negative high-voltage,lamp current,flow rate of carrier gas,flow rate of shielding gas,concentration of thiourea and ascorbic acid,concentration of the carrier medium,concentration of sodium borohydride.The linear range of the method was 0—40.0ng/mL with correlation coefficient of 1.0000.The detection limit was 0.02ng/mL.The relative standard deviation was 0.82%—1.86%.The recoveries of the method were from 95.10% to 102.20%.This method has simple operation,high sensitivity,lower detection limit and good repeatability,that could be applied to determination arsenic in food-additive phosphoric acid.