Gao-Long Zhang,Yong-Jin Yao,Guang-Xin Zhang,Zhen-Wei Jiao,Cheng-Jian Lin,Ya-Zhou Niu,Wei-Wei Qu,Lei Yang,Nan-Rou Ma,Lei Zheng,Hui-Ming Jia,Li-Jie Sun,Xing-Xing Liu,Xiao-Tong Chu,Jie-Cheng Yang,Jian-Song Wang,Shi-Wei Xu,Peng Ma,Jun-Bing Ma,Shi-Lun Jin,Zhen Bai,Mei-Rong Huang,Hong-Liang Zang,Biao Yang,Yang Liu
DOI: https://doi.org/10.1007/s41365-017-0249-0
2017-01-01
Nuclear Science and Techniques
Abstract:A detector setup for the measurement of angular distribution of heavy-ion elastic scattering at energies around Coulomb barrier on the radioactive ion beam line in Lanzhou at the heavy-ion research facility in Lanzhou is designed. The beam profile and the scattering angles on the target are deduced by two parallel plate avalanche counters, and four sets of detector telescopes (including double-sided silicon strip detectors) are placed systematically with the beam line, incorporating with Monte Carlo simulations. The data of \(^{16}\hbox {O}\) on \(^{89}\hbox {Y}\) target were analyzed to compare with the simulation results. It is found that the simulated distribution is agreeable with the experimental data. By assuming the pure Rutherford scattering at small scattering angles, the angular distribution of elastic scattering of \({}^{16}\hbox {O} + {}^{89}\hbox {Y}\) at low energies can be reasonably obtained. It indicates that this set of detector setup can be used for the measurement of angular distributions of heavy-ion elastic scattering at energies around Coulomb barrier.