ANALYSIS OF HEAT EXCHANGE BEHAVIOR CONCERNING AIR-FILM COOLING OF FIRST-STAGE BLADES OF ONE GAS TURBINE
MI Ke,CHU Guihong,QIU Luke,WANG Xinjun
DOI: https://doi.org/10.3969/j.issn.1002-3364.2012.06.019
2012-01-01
Abstract:By using the NUMERCA software,the external heat exchange behavior of first-steage blades,such as the surface temperature of blades,the effectiveness of air film,and the distribution of heat exchange coefficient etc.,boasting many rows of air film orifices opened on them of one gas turbine has been calculated and numerically analysed,and the heat exchange behavior of blade cascade being numerically verified.It shows that the predicted value Nu tallies well with the tested value.On the pressurized area,the surface temperature of blades can be reduced by 40% on the average,the average effectiveness of air film being about 0.7;on the suction area,the temperature reduced 30% on the average,the average effectiveness of air film being about 0.5;but,the temperature on cord-length region relative to 20% of the pressurized area,at standing points on front edge and on the tail edge of the suction area was higher,and the effectiveness of air film being lower.The given external behavior of blades can be used as design basis of blades' internal structure;at standing point on front edge inside the blades and on the cord-length rigion relative to 20% of the suction area,impact cooling has to be used,increasing the flow rate of cooling air at tail edge of the suction area,reducing thermal load on said region,so as to make the blades to be uniformly cooled.