Determination of Content and Related Substances in Ropivacaine Mesylate Injection by RP-HPLC

Wang Feng,Yang Weifeng,Zheng Jinqi
DOI: https://doi.org/10.3969/j.issn.1006-4931.2007.05.017
2007-01-01
Abstract:Objective A HPLC method was established for the determination of ropivacaine mesylate injection and its related substances.Methods The column was Agilent Zorbax C8 column(150 mm×4.6 mm,5 μm).The mobile phase to adjust the pH value to 5.4 with triethylamine 0.015 mol/L phosphate buffer-acetonitrile(75:25).The detection wavelength was 210 nm.The flow rate was 1.0 mL/min.Results Standard curve was linear in the range of 20.74-207.40 μg/mL and the correlation coefficient was 0.999 9.The average recovery rate was 100.0%(RSD=0.91%,n=9).The precision of intra-day(RSD < 0.5%)and inter-day(RSD < 0.5%)were good.The minimal detection range was 0.010 4 μg/mL.Conclusion This method is simple,rapid and the result is accurate.
What problem does this paper attempt to address?