Abstract:Objective:To investigate the application of intravascular ultrasound(IVUS)in evaluating drug-eluting stent implantation and guiding high-pressure balloon post-inflation in patients with acute coronary syndrome(ACS).Methods:Drug-eluting stents were implanted in 76 lesions of 45 patients with ACS.All patients were examined by coronary angiography(CAG)and IVUS before and after stent implantation.If IVUS criteria of optimal stent deployment were not met,post-inflation at higher pressure and reassessment with IVUS were performed.Results:The optimal criteria of CAG were achieved in 76 lesions of 45 patients with ACS,but optimal criteria of IVUS were not obtained in thirty-three lesions(43%)and were treated with high-pressure balloon post-inflation.Then another twenty-five lesions obtained the optimal criteria of IVUS,and the frequency of achieving the optimal criteria of IVUS increased from 57% to 89%(P<0.01).During follow-up of 1~10(median 5)months.There were two patients of recurrent angina.Conclusion:There is important clinical practical value that application of IVUS in evaluating stent implantation and guiding high-pressure balloon post-inflation.