Study on Optimization of Oxygen Candle Formula for Refuge Chamber

ZHANG Zheng,JIN Long-zhe,LIU Shu-ci,WANG Shu,GAO Na,LI Jing
2013-01-01
Abstract:Oxygen candle is a kind of high oxygen storage,good stability chemical oxygen source,but has problems such as high heat production and fast oxygen release,which can not completely meet the requirements of refuge chambers. To determine a suitable oxygen candle formula for refuge chambers,several tests carried out. By thermogravimetric tests,the research ranges of catalysts and fuels of oxygen candle were determined( 3%- 5% of Co3O4,Co2O3,Fe2O3and 4%- 8% of Fe,Mg,Mn). Accordingly,orthogonal combustion tests were designed,and by a comprehensive analysis of oxygen supply,oxygen release rate,the highest temperature of surface of oxygen candles,the optimum oxygen candle formula for refuge chamber is determined as follows: 88% NaClO3,6%Mn,5%Co2O3,1% kaolin. A characteristic test was conducted on a 2. 8 kg oxygen candle with the optimized formula and its characteristics are as follows: total oxygen supply 241. 0 L,oxygen production density 0. 3 L / g,oxygen evolution rate17. 3 L / min,utilization 88. 6%,harmful gases production CO≤0. 000 1%,CO2≤0. 06%,shell maximum temperature≤115. 1 ℃,ambient temperature≤33. 3 ℃,humidity≤31%. Bearing the relative parameters of refuge chamber in mind,the results meet the requirements. Therefore,the determined optimum oxygen candle formula is suitable for refuge chambers.