Study of intraocular lens power after LASIK in myopic patients

Jin-Ying Li,Chen Cao,Wei Wang,Chang Liu
DOI: https://doi.org/10.3980/j.issn.1672-5123.2013.11.43
2013-01-01
International Eye Science
Abstract:AIM: To evaluate the differences between Haigis-L formula and CH-SRK /T when predicting intraocular lens power after laser in situ keratomileusis( LASIK) surgery for myopia. METHODS: Seventy-two patients( 140 eyes,axial length ≤ 26mm) after LASIK surgery were recruited between October 2012 and February 2013. Participants with other ophthalmic diseases were excluded. Haigis-L and CH-SRK / T formula were used to calculate the intraocular lens power separately after LASIK surgery and the data were analyzed using SPSS 18. 0 software.RESULTS: The mean value of Hoyaintraocular lens after LASIK was 22. 99±1. 38D by Haigis-L formula compared with 19. 95±1. 69D using CH-SRK /T formula. According to paired t- test, pairs of differential mean are- 3. 039 ± 1. 899D. Wilcoxon signed rank test was used and the sum of ranks was-3. 408a( P=0.001). Meanwhile,the mean value of Allergan AR40 intraocular lens was 23. 26 ± 1. 49D by Haigis- L formula; while the degree of intraocular lens calculated by CH-SRK /T formula was 20. 05±1. 69D. According to paired t- test, pairs of differential mean are- 3. 208 ± 1. 823D. Wilcoxon signed rank test was used and the sum of ranks was-3. 408a( P=0.001).CONCLUSION: After LASIK surgery for myopia,the degree of intraocular lens power measured by CH- SRK /T is lower than that by Haigis-L formula. The degree of intraocular lens power calculated by CH- SRK /T is more likely to be under corrected.
What problem does this paper attempt to address?