Effect of Posterior Keratometry and Corneal Radius Ratio on the Accuracy of Intraocular Lens Formulas After Myopic LASIK/PRK

Yuxing Zheng,Jiaqing Zhang,Xiaotong Han,Ruoxuan Huang,Ling Wen,Jinfeng Ye,Yiguo Huang,Xiaozhang Qiu,Xiaoyun Chen,Xuhua Tan,Lixia Luo
DOI: https://doi.org/10.3928/1081597X-20240718-01
Abstract:Purpose: To investigate the impact of back-to-front corneal radius ratio (B/F ratio) and posterior keratometry (PK) on the accuracy of intraocular lens power calculation formulas in eyes after myopic laser in situ keratomileusis (LASIK)/photorefractive keratectomy (PRK) surgery. Methods: A retrospective, consecutive case series study included 101 patients (132 eyes) with cataract after myopic LASIK/PRK. Mean prediction error (PE), mean absolute PE (MAE), median absolute error (MedAE), and the percentage of eyes within ±0.25, ±0.50, and ±1.00 diopters (D) of PE were determined. Results: The Barrett True K-TK formula exhibited the lowest MAE (0.59 D) and MedAE (0.48 D) and the highest percentage of eyes within ±0.50 D of PE (54.55%) in total. In eyes with a B/F ratio of 0.70 or less and PK of -5.70 D or greater, the Potvin-Hill formula displayed the lowest MAE (0.46 to 0.67 D). Conclusions: The Barrett True-TK exhibited the highest prediction accuracy in eyes after myopic LASIK/PRK overall. However, for eyes with a low B/F ratio and flat PK, the Potvin-Hill performed best. [J Refract Surg. 2024;40(9):e635-e644.].