Analytical Model and Current Composite Control Strategy for Mid-Point Capacitor Three-Phase Four-Wire Shunt Active Power Filter

曹震,戴珂,谢斌,康勇
2008-01-01
Abstract:Three-phase four-wire shunt active power filters(APF)are often employed to compensate the harmonics and reactive current derived from non-linear load,as well as the negative-sequence and zero-sequence currents due to the unbalance of the load.This paper describes the analytical model for the mid-point capacitor three-phase four wire shunt active power filter.Since the reterence of the APF is AC harmonic signals,the performance under PI control is not satisfierd due to its limited bandwidth.Therefore,the paper gives a composite current control strategy,where the PI controller are parallel with repetitive controller to compensation harmonics together.The advanced repetitive controller is used to eliminate the steady current tracking error caused by cyclic disturbance signal to improve the compensation precision ,while the PI controller can ensure satisfied dynamic response performance.The feasibility and efficiency of the composite control architecture is verified completely by simulation and experimental results.
What problem does this paper attempt to address?