Fabrication of the Beam Splitters for Soft X-ray Laser Application

Zhanshan Wang,Yonggang Wu,Weixing Tang,Shuji Qin,Lingyan Chen,Xiangdong Xu,Yilin Hong,Shaojun Fu,Jie Zhu,Mingqi Cui
DOI: https://doi.org/10.1007/bf03183980
2003-01-01
Chinese Science Bulletin
Abstract:The soft X-ray interferometry is completed by the Mach-Zehnder interferometer using a soft X-ray laser, and it is also an important method to measure the electron densities of a laser-produced plasma near the critical surface. It is apparently demonstrated in this paper that the incident angle of each optical element in the soft X-ray Mach-Zehnder interferometer should be near normal incidence based on the polarized characteristics of the soft X-ray multilayers, and the product of reflectivity and transmission of the beam splitter should be taken as a standard of design according to the structure of the soft X-ray Mach-Zehnder interferometer. The beam splitters used in the soft X-ray interferometry at 13.9 nm are fabricated using the ion beam sputtering. The figure error of the beam splitter has reached the nanometer magnitude, in which the product of reflectivity and transmission of the beam splitter is more than 1.6%.
What problem does this paper attempt to address?