Experimental analysis of flow state for natural convection moist air under cryogenic frosting condition

An Pengjun,Xie Fushou,Chen Shuping,Yao Shuting,Han Hongyin
DOI: https://doi.org/10.3969/j.issn.1000-6516.2012.04.006
IF: 2.134
2012-01-01
Cryogenics
Abstract:Flow state of natural convection moist air was dynamically described under cryogenic frosting condition using a test bench of vertical plate designed specially and the temperature distribution near the vertical plate was analyzed.The experimental results show that moist air form a top-down main flow near the vertical plate and other directions are conducted into the main stream.The temperature of moist air decreases systematically from top to bottom along the tangential direction of the vertical plate and from far to near along the normal direction of vertical plate.
What problem does this paper attempt to address?