The Influence of Gap Distance on the Random Walk of Cathode Spot in Vacuum Arc

Zongqian Shi,Jia Xiao,Shenli Jia,Zhigang Liu,Lijun Wang
DOI: https://doi.org/10.1088/0022-3727/40/19/022
2007-01-01
Abstract:Experiments were conducted in a detachable vacuum chamber for Cu vacuum arc with arc current in the range 19-24 A. Experimental results indicated that the gap distance had a distinct influence on the characteristics of the random walk of the cathode spot ( CS) for the gap distance adopted, i.e. d = 4.8mm and d = 6.8 mm. It was found that the increase in the gap distance could lead to a larger diffusion parameter. Based on the dynamics of fragments constituting the CS, it was proposed that with a longer gap distance, the magnetic interaction between fragments would be strengthened. It would result in the increase of the mean step length of the CS and the decrease of the mean step time, which would lead to a larger diffusion parameter as observed. The plasma density in the region of the CS was also found to decrease with the increase in the gap distance. It would result in the CS having a higher probability of jumping to the contaminated region but not to the vicinity of the existing crater.