Design and Operation of Tank Gas Hydrogen Recovery through Membrane Separation

Wu Xuemei,He Gaohong,He zhen,Guo Duanhua
DOI: https://doi.org/10.3969/j.issn.1008-9411.2010.01.007
2010-01-01
Abstract:Pressure and temperature of tank gas purged from ammonia synthesis are relatively low.In this paper,membrane separation technique was applied to recover hydrogen from tank gas.The recovered hydrogen then returned back to the desulfuration unit as feed.With the increase of membrane area,concentration of hydrogen decreased whereas economic benefit increased due to the increasing recovery.Over 287.7×104 Yuan/a's benefit could be reached at the feed-in of tank gas 1300Nm3/h,pressure of permeated gas 0.8MPa and concentration of hydrogen 85-90% as required.The recovery term of investment was within 17 months.During the operation of the separator,decrease of selective coefficient of H/N and increase of gas pressure may cause decrease of hydrogen recovery and economic benefit.There are little effect of the above two factors on concentration of hydrogen.
What problem does this paper attempt to address?