Effect of Electrode Parameters on Particles Elimination by Using Electric Coagulation Indoor Air Cleaning System

CAI Bing,WEI Ji-ying,JIANG Feng,ZHANG Zhen-zhong
DOI: https://doi.org/10.3321/j.issn:1000-7857.2006.07.010
2006-01-01
Abstract:A new type electric coagulation indoor air cleaning system, which had an excellent effect on particles elimination in indoor air, was introduced in this paper. The effect of electrode parameters on particles elimination by using electric coagulation indoor air cleaning system was studied in detail. The results showed that there was an optimum status between alternating current (440 V) and direct current (12 kV) in our experiments. The electrode parameters had a remarkable influence on small particles whose diameter was less than 1 μm, whereas the effect was indistinctive when the particle's diameter was in excess of 1 μm.
What problem does this paper attempt to address?