Effects of Acoustic and Pulse Corona Discharge Coupling Field on Agglomeration and Removal of Coal-fired Fine Particles

Mingchun He,Zhongyang Luo,Mengshi Lu,Shuxin Liu,Mengxiang Fang
DOI: https://doi.org/10.4209/aaqr.2018.08.0306
2019-01-01
Aerosol and Air Quality Research
Abstract:Fine particles from coal-fired power plants are harmful to human health and the atmosphere. Traditional electrostatic precipitators (ESPs) exhibit low efficiency in removing such particles. By contrast, pulsed corona discharge and high-intensity acoustic waves are effective pretreatment methods by which fine particles can be agglomerated into larger particles. Coupling these two fields can enhance the agglomeration process. In this study, a laboratory-scale experimental setup was established to investigate the agglomeration and efficient removal of fine particles. According to the results, application of the coupling field increased the median particle diameter (D-50) and agglomeration ratio (R-ae) compared with use of a single field. Under the coupling field approach, when pulse input and acoustic wave parameters were 55 kV-100 Hz and 143 dB-1600 Hz, respectively, D-50 and R-ae reached 73.28 mu m and 9.18, respectively, and numerous fine particles agglomerated into large particles that could be removed using an ESP. Furthermore, the overall efficiency of removing fine particles increased to 98.3% under optimal conditions compared with the 80.7% efficiency exhibited when pretreatment was not applied.