Test Precision on the Scanning Performance in Laser Imaging Radar

刘丽萍,孙秀冬,赵远,张勇,靳辰飞,刘琦
DOI: https://doi.org/10.3969/j.issn.1007-2276.2008.06.016
2008-01-01
Infrared and Laser Engineering
Abstract:A scanning laser test equipment was developed to precisely measure the scanning system performance of a scanning imaging laser radar. The test precision analysis on the scanning laser test equipment was accomplished. The methods of improving the test precision of the scanning laser test equipment were studied in particular. According to the test principle and the use characteristic of the scanning laser test equipment, two improved precision methods were brought forward. One was to correct the distortion of the optical system of test equipment in data processing course that could depress the detecting error of light point position at CCD. The other was to measure the focal length of the optical system of test equipment with high precision by two times imaging. The analysis showed that test precision of the scanning angle could be enhanced by one order through adopting the two methods above. Both experiment and analysis results show that test precision of the scanning angle of the scanning laser test equipment could be up to 1.2 mrad. In conclusion, the scanning laser test equipment studied in this paper can measure the scanning system performance for scanning imaging laser radar in high precision.
What problem does this paper attempt to address?